Testing Chambers
Stability Chamber Manufacturers in Ahmedabad
We are also supply in Andhra Pradesh, Arunachal Pradesh, Assam, Bihar, Chhattisgarh, Goa, Gujarat, Haryana, Himachal Pradesh, Jharkhand, Karnataka, Kerala, Madhya Pradesh, Maharashtra, Manipur, Meghalaya, Mizoram, Nagaland, Odisha, Punjab, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, Uttar Pradesh, Uttarakhand, and West Bengal
UNIQUE FEATURES
Ergonomic Design
Flexible & Space Saving Stability Chamber
Superior Functionality
Negligible Maintenance
High Temperature Accuracy
Better Temperature Uniformity
Long-Term stability tests
The Stability Chamber is designed to simulate and control environmental conditions such as temperature and humidity to assess the stability of products over time. It is essential for testing the shelf life and performance of pharmaceuticals, chemicals, and other products under controlled conditions.
TECHNICAL DATA
For conditions as per ICH guidelines (International Conference of Harmonization) 25°C -60% RH/40°C -75% RH/30°C -65% RH/ 25°C-40% RH/40°C -25% RH/30°C-35% RH.
Temperature Range: 10.0°C to 60.0°C
Accuracy/Uniformity: ±0.1°C/+1°C
Humidity Range: 25% to 95% RH
Accuracy/Uniformity: ±2% RH / ± 3% RH
Temperature/Humidity display: Digital LED 3.5 digit.
Control: Microprocessor based PID control Auto tune.
Resolution: 0.1°C/1% RH
Temperature sensor: PT-100
RH sensor: Direct capacitance type
Heating: 'U' shaped tubular heater in stainless steel.
Cooling: CFC free Copeland make compressor utilizing R 134A eco friendly refrigerant, with condenser, motor and relay or as per the requirement of customer for higher accuracy.
Steam injection: Boiler with reservoir made of thick stainless steel, with heater, water inlet control, low water level safeguard
Air circulation: cooling type fan with impellar/blower and flange type motor.
Construction: Double wall, outer cabinet mild steel powder coated and inner chamber stainless steel 304 grade, Double door - outer metal body and inner acrylic door.
Chamber illumination: Fluorescent light with door switch.
Castor wheels for easy move ability with minimum weights bearing of 50kg.
Trays: Stainless steel wire mesh heavy duty.
Electrical: 230V/15A/50 Hz
Calibration certificate by ERTL - Mumbai with traceability ERTL.
SAFETY FEATURES
High Temperature safety cut off
Low water level boiler cut off
Electrical overload cutoff relay for compressor
Time delay for compressor switch ON
Electrical circuit breaker
PRE INSTALLATION MANDATORY REQUIREMENT
(Guarantee void in case of non compliance)
a) Distilled water or DM water continuous supply with tap for boiler input of % "BSP at 3 feet height.
b) Room temperature around machine preferably at 25°C with air conditioning or a well ventilated room with exhaust fan. However, surrounding temperature should not exceed 30°C.
c) Stabilized input voltage of 230V A.C Amps. Use of servo controlled stabilizer is recommended.
d) Water Drain line with 1/2" nozzle to be provided at floor level.
OPTIONAL ACCESSORIES
Micro PLC Based Control & Recording System for Reach in stability testing chamber with in-built Recording, PC Interface with 21 CFR Software, DOT - Matrix Printer Interface.
R.H. Imported Sensor for 100% RH Readings.
Standby Refrigeration Systems as per capacity.
PLC for auto change over for standby refrigeration.
CFR 21 part 11 compliance software for PLC with Rs. 485 or Ethernet Communication.
Data Logger for Rs. 485 communication system with PC Connectivity.
4, 8 and 12 channel Data Scanner complete with sensor RH and PT-100 Sensor.
SMS Mobile alert system.
Door Access Security system.
Safety Digital Temperature Controller
Timer
Recommended Stabilizer.
Send Message