Chennai

'sterilizing machine'

Items tagged with 'sterilizing machine'

product image
Autoclave

Autoclave Vertical Manufacturers in Ahmedabad We are also supply in Andhra Pradesh, Arunachal Pradesh, Assam, Bihar, Chhattisgarh, Goa, Gujarat, Haryana, Himachal Pradesh, Jharkhand, Karnataka, Kerala, Madhya Pradesh, Maharashtra, Manipur, Meghalaya, Mizoram, Nagaland, Odisha, Punjab, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, Uttar Pradesh, Uttarakhand, and West Bengal UNIQUE FEATURES: Easy to use Negligible Maintenance DESCRIPTION: Double walled construction fully made of Stainless Steel 304 Q. Electrically operated Supplied with Two Safety Valves, Pressure gauge, Steam Release Valve, Drain Valve at bottom. Fitted with Jointless Silicon Rubber Gasket. Foot lifting arrangement to open lid. I.S.I approved heating elements. Vertical autoclave, also known as steam sterilizers and top loading sterilizers, is a sterilizing machine that comes in a cylindrical shape. These machines help in sterilization of medical equipment, surgical instruments to name a few. This machines help in sterilization in Lab, Hospitals and Industry. TECHNICAL DATA Working pressure upto 15 PSI Power Supply: 230 Volts Chamber Size A.C. 50 Hz Single Phase OPTIONAL ACCESSORIES Digital Temperature controller cum indicator with timer. Low water level cut off Pressure cut off Switch Basket Stainless Steel

Send Message
product image
Autoclave

Autoclave Vertical (Fully Automatic) Manufacturers in Ahmedabad We are also supply in Andhra Pradesh, Arunachal Pradesh, Assam, Bihar, Chhattisgarh, Goa, Gujarat, Haryana, Himachal Pradesh, Jharkhand, Karnataka, Kerala, Madhya Pradesh, Maharashtra, Manipur, Meghalaya, Mizoram, Nagaland, Odisha, Punjab, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, Uttar Pradesh, Uttarakhand, and West Bengal UNIQUE FEATURES: Ergonomic Design Easy to use Superior Functionality DESCRIPTION: Double walled construction fully made of Stainless Steel 304 Q. Electrically operated Supplied with Two Safety Valves, Pressure gauge, Steam Release Valve, Drain Valve at bottom. Fitted with Jointless Silicon Rubber Gasket. Foot lifting arrangement to open lid. I.S.I approved heating elements. An automatic autoclave is a piece of specialized sterilization equipment that works by elevating the temperature and adjusting the pressure of the chamber inside. Before an automatic autoclave begins, it must first remove any air that is trapped in the chamber, as trapped outside air is detrimental to sterility. Also known as steam sterilizers and top loading sterilizers, is a sterilizing machine that comes in a cylindrical shape. These machines help in sterilization of medical equipment, surgical instruments to name a few. This machines help in sterilization in Lab, Hospitals and Industry. TECHNICAL DATA: Working Pressure : Upto 15 PSI Working Temperature: 121°C to 125°C Temp. Controller cum timer : P.I.D Temperature Controller Microprocessor (LED Display) for Temperature & Timer complete unit with automatic air purging Digital Temperature Control & Indicator 0.1°C resolution, with electronic digital timer range 0 to 99 minutes. Autoclaving time cycle automatically starts when set pressure is achieved, Automatic steam release once autoclaving cycle complete. Solenoid Valve system : This valve works for automatic purging and automatic steam release when cycle time is complete. Safety Protection for heater : Low water cut off assembly connected to heater which automatically cuts off power to the heater if the water level is not sufficient. Power Supply : 230 Volts A.C 50 Hz Single phase. OPTIONAL ACCESSORIES Basket Stainless Steel. Single Channel Data Logger with Scanner to store 3,00,000 Reading with Pen drive attachment to collect data.

Send Message
product image
Testing Chambers

Stability Chamber Manufacturers in Ahmedabad We are also supply in Andhra Pradesh, Arunachal Pradesh, Assam, Bihar, Chhattisgarh, Goa, Gujarat, Haryana, Himachal Pradesh, Jharkhand, Karnataka, Kerala, Madhya Pradesh, Maharashtra, Manipur, Meghalaya, Mizoram, Nagaland, Odisha, Punjab, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, Uttar Pradesh, Uttarakhand, and West Bengal UNIQUE FEATURES Ergonomic Design Flexible & Space Saving Stability Chamber Superior Functionality Negligible Maintenance High Temperature Accuracy Better Temperature Uniformity Long-Term stability tests The Stability Chamber is designed to simulate and control environmental conditions such as temperature and humidity to assess the stability of products over time. It is essential for testing the shelf life and performance of pharmaceuticals, chemicals, and other products under controlled conditions. TECHNICAL DATA For conditions as per ICH guidelines (International Conference of Harmonization) 25°C -60% RH/40°C -75% RH/30°C -65% RH/ 25°C-40% RH/40°C -25% RH/30°C-35% RH. Temperature Range: 10.0°C to 60.0°C Accuracy/Uniformity: ±0.1°C/+1°C Humidity Range: 25% to 95% RH Accuracy/Uniformity: ±2% RH / ± 3% RH Temperature/Humidity display: Digital LED 3.5 digit. Control: Microprocessor based PID control Auto tune. Resolution: 0.1°C/1% RH Temperature sensor: PT-100 RH sensor: Direct capacitance type Heating: 'U' shaped tubular heater in stainless steel. Cooling: CFC free Copeland make compressor utilizing R 134A eco friendly refrigerant, with condenser, motor and relay or as per the requirement of customer for higher accuracy. Steam injection: Boiler with reservoir made of thick stainless steel, with heater, water inlet control, low water level safeguard Air circulation: cooling type fan with impellar/blower and flange type motor. Construction: Double wall, outer cabinet mild steel powder coated and inner chamber stainless steel 304 grade, Double door - outer metal body and inner acrylic door. Chamber illumination: Fluorescent light with door switch. Castor wheels for easy move ability with minimum weights bearing of 50kg. Trays: Stainless steel wire mesh heavy duty. Electrical: 230V/15A/50 Hz Calibration certificate by ERTL - Mumbai with traceability ERTL. SAFETY FEATURES High Temperature safety cut off Low water level boiler cut off Electrical overload cutoff relay for compressor Time delay for compressor switch ON Electrical circuit breaker PRE INSTALLATION MANDATORY REQUIREMENT (Guarantee void in case of non compliance) a) Distilled water or DM water continuous supply with tap for boiler input of % "BSP at 3 feet height. b) Room temperature around machine preferably at 25°C with air conditioning or a well ventilated room with exhaust fan. However, surrounding temperature should not exceed 30°C. c) Stabilized input voltage of 230V A.C Amps. Use of servo controlled stabilizer is recommended. d) Water Drain line with 1/2" nozzle to be provided at floor level. OPTIONAL ACCESSORIES Micro PLC Based Control & Recording System for Reach in stability testing chamber with in-built Recording, PC Interface with 21 CFR Software, DOT - Matrix Printer Interface. R.H. Imported Sensor for 100% RH Readings. Standby Refrigeration Systems as per capacity. PLC for auto change over for standby refrigeration. CFR 21 part 11 compliance software for PLC with Rs. 485 or Ethernet Communication. Data Logger for Rs. 485 communication system with PC Connectivity. 4, 8 and 12 channel Data Scanner complete with sensor RH and PT-100 Sensor. SMS Mobile alert system. Door Access Security system. Safety Digital Temperature Controller Timer Recommended Stabilizer.

Send Message
product image
Testing Chambers

Humidity Chamber Manufacturers in Ahmedabad We are also supply in Andhra Pradesh, Arunachal Pradesh, Assam, Bihar, Chhattisgarh, Goa, Gujarat, Haryana, Himachal Pradesh, Jharkhand, Karnataka, Kerala, Madhya Pradesh, Maharashtra, Manipur, Meghalaya, Mizoram, Nagaland, Odisha, Punjab, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, Uttar Pradesh, Uttarakhand, and West Bengal UNIQUE FEATURES Ergonomic Design Flexible & Space Saving Stability Chamber Superior Functionality Negligible Maintenance High Temperature Accuracy Better Temperature Uniformity Long-Term stability tests The Humidity Chamber is designed to provide precise temperature and humidity regulation for accurate and consistent testing. It is ideal for applications requiring controlled environmental conditions, such as material testing, stability studies, and product development. TECHNICAL DATA For conditions as per ICH guidelines (International Conference of Harmonization) 25°C -60% RH/40°C -75% RH/30°C -65% RH/ 25°C-40% RH/40°C -25% RH/30°C-35% RH. Temperature Range: 10.0°C to 60.0°C Accuracy/Uniformity: ±0.1°C/+1°C Humidity Range: 25% to 95% RH Accuracy/Uniformity: ±2% RH / ± 3% RH Temperature/Humidity display: Digital LED 3.5 digit. Control: Microprocessor based PID control Auto tune. Resolution: 0.1°C/1% RH Temperature sensor: PT-100 RH sensor: Direct capacitance type Heating: 'U' shaped tubular heater in stainless steel. Cooling: CFC free Copeland make compressor utilizing R 134A eco friendly refrigerant, with condenser, motor and relay or as per the requirement of customer for higher accuracy. Steam injection: Boiler with reservoir made of thick stainless steel, with heater, water inlet control, low water level safeguard Air circulation: cooling type fan with impellar/blower and flange type motor. Construction: Double wall, outer cabinet mild steel powder coated and inner chamber stainless steel 304 grade, Double door - outer metal body and inner acrylic door. Chamber illumination: Fluorescent light with door switch. Castor wheels for easy move ability with minimum weights bearing of 50kg. Trays: Stainless steel wire mesh heavy duty. Electrical: 230V/15A/50 Hz Calibration certificate by ERTL - Mumbai with traceability ERTL. SAFETY FEATURES High Temperature safety cut off Low water level boiler cut off Electrical overload cutoff relay for compressor Time delay for compressor switch ON Electrical circuit breaker PRE INSTALLATION MANDATORY REQUIREMENT (Guarantee void in case of non compliance) a) Distilled water or DM water continuous supply with tap for boiler input of % "BSP at 3 feet height. b) Room temperature around machine preferably at 25°C with air conditioning or a well ventilated room with exhaust fan. However, surrounding temperature should not exceed 30°C. c) Stabilized input voltage of 230V A.C Amps. Use of servo-controlled stabilizer is recommended. d) Water Drain line with 1/2" nozzle to be provided at floor level. OPTIONAL ACCESSORIES Micro PLC Based Control & Recording System for Reach in stability testing chamber with in-built Recording, PC Interface with 21 CFR Software, DOT - Matrix Printer Interface. R.H. Imported Sensor for 100% RH Readings. Standby Refrigeration Systems as per capacity. PLC for auto change over for standby refrigeration. CFR 21 part 11 compliance software for PLC with Rs. 485 or Ethernet Communication. Data Logger for Rs. 485 communication system with PC Connectivity. 4, 8 and 12 channel Data Scanner complete with sensor RH and PT-100 Sensor. SMS Mobile alert system. Door Access Security system. Safety Digital Temperature Controller Timer Recommended Stabilizer.

Send Message

Still searching for
sterilizing machine?